Direktori Produk

Filter Pencarian

Negara

Indonesia (29)

Semua Negara (29)

Kategori Perusahaan

Manufacturer (29)

Semua Kategori (29)


Reset pencarian

Produk terkait

    • JL MH THAMRIN BLOK A1-L, Delta Silicon Industrial Park Kab. Bekasi
    • Jalan Kebon Sirih No. 71 Kota Adm. Jakarta Pusat
    • Jalan Kebon Sirih No. 71 Kota Adm. Jakarta Pusat
  • BARE ALUMINIUM CONDUCTOR - AAC
    Rated Voltage : - Specification : SPLN 41-6 : 1981 Classification : Bare Conductor Application : Overhead Transmission and Distribution Construction : Stranded All Aluminium Conductor
    • Raya Bogor Km. 49, Jln Roda Pembangunan No.5 Kab. Bogor
  • BARE ALUMINIUM CONDUCTOR
    Feature The conductors are applied for overhead power transmission purposes, medium tension overhead systems and distribution networks. CONSTRUCTION Conductor Seven of more aluminium wires of the same nominal diameter are twisted together in concentric layers. When conductor consists of more than one layer, successive layers are twisted in opposite directions which is defined as right-hand lay (Z) or left-hand lay (S). All Aluminium Conductor (AAC) The conductor shall be constructed of hard drawn aluminium wires with 99,45% minimum purity of aluminium. The maximum resistivity at 20o C is 0.028264 ohm.mm²/m. All Aluminium Alloy Conductor (AAAC) The conductor shall be constructed of hard drawn aluminium alloy wires which consists of: minimum 97,28% Aluminium              ± 0,5 % Magnesium              ± 0 5 % Silicon  The maximum resistivity at 20° C is 0.0328 ohm.mm²/m Aluminium Conductor Steel Reinforced (ACSR) The conductor shall be constructed of All Aluminium Conductor (AAC) and one or stranded seven Galvanized Steel Wires as a core, together built up in concentric layers. The galvanized steel wires which is used as a core shall be heat treatment and Zinc coated uniformly by using the method of hot dipped or electrolyte zinc coated. Aluminium-Clad Steel Core Thermal Resistant Aluminium Alloy (TACSR/AS) The conductor shall be constructed of Thermal Resistant Aluminium Alloy wires (TAL wires) and stranded seven Aluminium-clad Steel wires (AS wires) as a core, together built up in concentric layers. The tensile strength of TAL wire after heating 230° C for one hour shall be more 90% than the value before heating. And the conductivity is more of 60% IACS (International Annealed Copper Standard). The conductivity of AS wire is 20.3% - 23.0% IACS. Type : AAC (All Aluminium Conductor) HAL (Hard-drawn Aluminium Stranded Conductor) AAAC (All Aluminium Alloy Conductor) ACSR (Aluminium Conductor Steel Reinforced) TACSR/AS (Aluminium-clad Steel Core Thermal Resistant Aluminium Alloy) Specification :  SPLN 41- 6:1981 for AAC JIS C 3109-1994 for HAL SPLN 41- 8:1981 for AAAC SPLN 41- 7:1981 for ACSR JFEPC A 242:1977 for TACSR/AS (Other specifications are available upon request)
    • Jl. Raya Narogong Km.16 Kab. Bogor
  • ALUMINIUM RODS
    Our aluminium and Copper Casting plants supply for both internal and external requirement of quality rods, either for cable or other industrial use. Overhead Bare Conductors are used to deliver power in High or Very High Transmission Lines connecting Power Generating Plant and its Substations. The conductors are stranded aluminium alloy, like AAC, AAAC, ACAR, ACSR, ACSR/TW, ACSR/AW, TACSR, etc. Overhead insulated Conductors are designed for overhead MV distribution (AAAC/XLPE, MV ABC) or Service Drop cables (LV ABC).
    • Jl. Raya Bekasi Km 23.1 (PO. Box 2468, Jakarta 10001) Kota Adm. Jakarta Timur
  • BARE COPPER CONDUCTOR
    Feature The conductors are applied for overhead power transmission purposes. CONSTRUCTION Conductor Seven or more copper wires the same nominal diameter are twisted together in concentric layers. When conductor consists of more than one layer, alternate layers are twisted in opposite directions which is defined as right-hand lay (Z) or left-hand lay (S). Bare Copper Conductor - Hard (BCC-H) The conductor has mechanic characteristic minimum 428 N/mm². The maximum resistivity at 20° C is 0.01786 ohm. mm²/m. Bare Copper Conductor - Half Hard (BCC-1/2H) The conductor has mechanic characteristic between minimum 340 N/mm². Maximum 410 N/mm². The maximum resistivity at 20° C is 0.01784 ohm.mm²/m. Annealed Copper Wire (BCC Soft) The conductor has maximum resistivity at 20° C is 0.017241 ohm.mm²/m. Specification : SPLN 41-4:1981 SPLN 41-5:1981  JIS C 3102 (Other specification are available upon request) Type : Bare Copper Conductor - Half Hard (BCC-1/2H) - Bare Copper Conductor - Hard (BCC-H) - Annealed Copper Wire (BCC-Soft)
    • Jl. Raya Narogong Km.16 Kab. Bogor
  • AAAC
    Specification:   All alloy aluminium conductor SPLN 41-8:1981 Application : This All Alloy Aluminium Conductor cable is a concentric lay-stranded bare conductor consisting of aluminium alloy wires available in both single layer and multi layer constructions. AAAC conductor provide higher corrosion resistance than ACSR conductors.  
    • Jl. Rungkut Industri Raya 17-A Kota Surabaya
  • COPPER RODS
    Our aluminium and Copper Casting plants supply for both internal and external requirement of quality rods, either for cable or other industrial use. Overhead Bare Conductors are used to deliver power in High or Very High Transmission Lines connecting Power Generating Plant and its Substations. The conductors are stranded aluminium alloy, like AAC, AAAC, ACAR, ACSR, ACSR/TW, ACSR/AW, TACSR, etc. Overhead insulated Conductors are designed for overhead MV distribution (AAAC/XLPE, MV ABC) or Service Drop cables (LV ABC).
    • Jl. Raya Bekasi Km 23.1 (PO. Box 2468, Jakarta 10001) Kota Adm. Jakarta Timur
  • GALVANIZED STEEL WIRE
    Galvanized Steel Wire Ref. Standard   :  JIS G.3537 Construction    : Galvanized Steel wire stranded Size range       : 6 ~ 135 mm² Application       : Ground wire
    • Kedoya Elok Plaza Blok DD No. 75 -76 Jl. Panjang Kota Adm. Jakarta Barat