Direktori Produk

Filter Pencarian

Negara

indonesia (3)

Indonesia (66)

Semua Negara (69)

Kategori Keanggotaan

Platinum (25)

Free (19)

Semua Kategori Member (44)

Kategori Perusahaan

Manufacturer (5)

Distributor (42)

Supplier (4)

Fabricator (5)

Contractor (13)

Semua Kategori (69)


Reset pencarian

Produk terkait

  • KWP-BLOC (NON-CLOGGING IMPELLER PUMP), KSB INDONESIA
    Design 
    Horizontal, radially split volute casing pump in closecoupled design, single-stage, single-entry, available with various impeller types: non-clogging impeller and free-flow impeller. 
    Applications 
    Handling of pre-treated sewage, waste water, all types of slurries without stringy substances and pulps up to 5 % bone dry with a maximum density of 1.1 kg/dm3. Overview of technical data Type of impeller Closed; Multi-vane impeller;Free flow impeller;Radial Type of installation Close- coupled Maximum drive rating 22 kW Impeller material (EN standard) ERN; NORIDUR 1.4593 Type of bearing Rolling element bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 500 1/min Maximum flow rate 330 m³/h Maximum discharge-side pressure 10 bar Casing material (EN standard) NORIDUR 1. 4593;JL 1040 No. of impeller entries Single entry Casing material Duplex steel; Cast iron Minimum flow rate 4 m³/h Suction characteristics Non- priming Drive voltage Low voltage eClass assignment 36410000; 36410100;36410103;36410101 Pull-out design Yes Pump set location Dry installed Max. permissible fluid temperature 100 002 Free passage 70 mm Main applications Industry and process engineering Type of installation Stationary Type of casing Volute casing Type of connection Flange Type of lubrication Grease lubrication Type of drive Electric motor Installation position Horizontal or vertical Shaft material (EN standard) 1. 4021;1.4462 Type of coupling Direct Shaft seal type Mechanical seal Maximum head 100, 00 m Maximum rated pressure (discharge) PN 10 Minimum head 2, 00 m Nozzle position End suction Casing partition Radially split

    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • (HIGH-PRESSURE PUMPS), KSB INDONESIA
    Design 
    Horizontal, radially split, product-lubricated, multistage ring-section pump with radial impellers, axial and radial single-entry inlet. 
    Applications 
    Handling of feed water in power stations, boiler feed water and condensate in industrial facilities. Overview of technical data Type of installation Long- coupled Maximum drive rating 1. 200 kW Type of bearing Plain bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 600 1/min Maximum flow rate 274 m³/h Maximum discharge-side pressure 140 bar No. of impeller entries Single entry Casing material Chrome steel; Cast steel Minimum flow rate 8 m³/h Suction characteristics Non- priming Drive voltage Low voltage, high voltage eClass assignment 36410101; 36410000;36410100 Other impeller types Closed / Radial Pump set location Dry installed Type of suction casing Annular casing Max. permissible fluid temperature 160 002 UNSPSC classification 4015150300 Type of discharge casing Annular casing Type of first impeller Closed / Radial Main applications Industry and process engineering; Energy Type of installation Stationary Type of connection Flange Type of lubrication Oil / Product lubrication Type of drive Electric motor, turbine Installation position Horizontal Maximum suction pressure 7 bar Type of coupling Direct Shaft seal type Mechanical seal Maximum head 1. 400,00 m Maximum rated pressure (discharge) PN 64, PN 100, PN 160 Minimum head 200, 00 m Type of stage casing Stage casing with diffuser Nozzle position Variable Casing partition Radially split

    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • SECOCHEM EX (CANNED MOTOR PUMPS), KSB INDONESIA
    Design 
    Horizontal, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single -entry, casing connecting dimensions to EN 22 858 / ISO 2858. Design to ATEX. 
    Applications 
    Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry. Overview of technical data Type of impeller Radial; Closed / Radial;Multi-vane impeller;Closed Type of installation Long- coupled Maximum drive rating 70 kW Impeller material (EN standard) 1. 4408;JL 1040;NORIDUR 1.4593 Type of bearing Plain bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 500 1/min Maximum flow rate 300 m³/h Maximum discharge-side pressure 25 bar Casing material (EN standard) NORIDUR 1. 4593;1.4408;GP240GH;JS 1025 No. of impeller entries Single entry Casing material Cast steel; Cast iron;Cast stainless steel Minimum flow rate 1 m³/h Suction characteristics Non- priming Drive voltage Low voltage eClass assignment 36410101; 36410000;36410100 Pull-out design Yes Pump set location Dry installed Explosion protection II 2 G EEX DE IIC T4; II 2 G EEX DE IIC T5;II 2 G EEX DE IIC T3;II 2 G EEX DE IIC T6 Heatable Yes Max. permissible fluid temperature 350 002 Main applications Industry and process engineering Type of installation Stationary Type of casing Volute casing Type of connection Flange Type of lubrication Product lubrication Type of drive Electric motor Installation position Horizontal Shaft material (EN standard) 1. 4462 Type of coupling None; Direct Shaft seal type Canned motor pump Drive IEC standardized motor Maximum head 220, 00 m Maximum rated pressure (discharge) PN 25 Minimum head 14, 00 m Nozzle position End suction Casing partition Radially split Connection to power supply 220/ 400/690 V, 3~

    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • CINCP / CINCN (WET WELL PUMPS), KSB INDONESIA
    Design
    Vertical "CANTILEVER" pump with base plate for pits and tanks. Cantilever shaft without friction bearings supported by bearings on the top. Semi-open impeller. CINCP supplied with discharge pipe up to the outside of the base plate. CINCN without discharge pipe. Design to ATEX. 
    Applications
    Aggressive chemical fluids which may be slightly contaminated or have a low solids content in the chemical and petrochemical industry.] Overview of technical data Type of impeller Open Maximum drive rating 184 kW Impeller material (EN standard) CA6NM; CF8M;JL 1040 Type of bearing Rolling element bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 500 1/min Maximum flow rate 320 m³/h Maximum discharge-side pressure 10 bar Top plate Yes Casing material (EN standard) CA6NM; CF8M;JL1040 Minimum flow rate 0, 70 m³/h Suction characteristics Non- priming Drive voltage Low voltage Pump set location Dry installed, floodable Max. permissible fluid temperature 100 °C Type of first impeller Single entry Main applications Industry and process engineering; Water Type of installation Stationary Type of casing Volute casing Type of lubrication Grease / Oil lubrication Type of drive Electric motor Installation position Vertical Shaft material (EN standard) AISI- 316L;F-114 Type of coupling Direct Shaft seal type Shaft seal ring Drive Electric motor Maximum head 95, 00 m Minimum head 3, 50 m Explosion protection ATEX ( 94/9/EC) Casing partition Radially split Maximum submergence 1. 585 mm Connection to power supply 230/ 400 V, 3~
    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • (DRY WELL PUMPS), KSB INDONESIA
    Design 
    Horizontal, radially split volute casing pump in back pull-out-design, single-stage, single-entry, available with various impeller types: non-clogging impeller, open multi-vane impeller, free-flow impeller. Design to ATEX. 
    Applications 
    Handling of pre-treated sewage, waste water, all types of slurries without stringy substances and pulps up to 5 % bone dry with a maximum density of 1.4 kg/dm3. Overview of technical data Type of impeller Free flow impeller; Closed;Radial;Multi-vane impeller;Open Type of installation Long- coupled Maximum drive rating 1. 500 kW Impeller material (EN standard) CERAMIKPOLYSIC; ERN;NORICHROM;NORICLOR;NORIDUR 1.4593;NORIHARD Type of bearing Rolling element bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 500 1/min Maximum flow rate 15. 000 m³/h Maximum discharge-side pressure 10 bar Casing material (EN standard) CERAMIKPOLYSIC; JL1040;NORICLOR;NORICROM;NORIDUR 1.4593;NORIHARD No. of impeller entries Single entry Casing material Special cast material; Cast iron;Duplex steel Minimum flow rate 4 m³/h Suction characteristics Non- priming Drive voltage Low voltage, high voltage eClass assignment 36410101; 36410000;36410100;36410103 Pull-out design Yes Pump set location Dry installed Max. permissible fluid temperature 280 002 Free passage 250 mm Main applications Industry and process engineering; Water;Waste water / sewage;Energy;Mining / Dredges Type of installation Stationary Type of casing Volute casing Type of connection Flange Type of lubrication Oil lubrication Type of drive Electric motor Installation position Horizontal Shaft material (EN standard) C45+ N Type of coupling Jack shaft / Belt drive;Direct;Gear Shaft seal type Mechanical seal; Gland packing Maximum head 140, 00 m Maximum rated pressure (discharge) PN10 Minimum head 1, 00 m Nozzle position End suction Casing partition Radially split

    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • HGB(RING-SECTION PUMPS), KSB INDONESIA
    Design 
    Horizontal, radially split, multistage ring-section pump with radial impellers, single- or double-entry. 
    Applications 
    Handling of feed water and condensate in power stations and industrial facilities, generation of pressurized water for bark peeling machines, descaling equipment, snow guns, etc. Overview of technical data Type of installation Long- coupled Maximum drive rating 5. 000 kW Type of bearing Rolling element and plain bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 7. 000 1/min Maximum flow rate 1. 650 m³/h Maximum discharge-side pressure 200 bar No. of impeller entries Single / Double entry Casing material Carbon steel Minimum flow rate 15 m³/h Suction characteristics Non- priming Drive voltage Low voltage, high voltage eClass assignment 36410100; 36410000;36410101 Other impeller types Closed / Radial Pump set location Dry installed Type of suction casing Annular casing Max. permissible fluid temperature 200 002 Type of discharge casing Annular casing Type of first impeller Single entry / Double entry Main applications Industry and process engineering; Energy Type of installation Stationary Type of connection Flange, loose flange Type of lubrication ( forced) oil lubrication Type of drive Electric motor, turbine Installation position Horizontal Maximum suction pressure 30 bar Type of coupling Geared variable speed coupling; Gear;Variable speed coupling;Direct Shaft seal type Mechanical seal; Gland packing Maximum head 2. 000,00 m Maximum rated pressure (discharge) PN 63, PN 100, PN 160, PN 250 Minimum head 300, 00 m Type of stage casing Stage casing with diffuser Nozzle position Variable Casing partition Radially split

    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
    • Gedung Hayam Wuruk Indah Gedung HWI Lindeteves Lt. 2; Block B37 Kota Administrasi Jakarta Barat
    • +62 21 62318093
    • +62 21 62302763
  • MAGNOCHEM-BLOC (MAG-DRIVE PUMPS), KSB INDONESIA
    Design 
    Horizontal, seal-less, close-coupled, mag-drive volute casing pump to ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Design to ATEX. 
    Applications 
    Handling of aggressive, toxic, explosive, valuable, flammable, malodorous or harmful liquids in the chemical, petrochemical and general industry. Overview of technical data Type of impeller Multi- vane impeller;Closed;Closed / Radial;Radial Type of installation Close- coupled Maximum drive rating 90 kW Impeller material (EN standard) 1. 4408;JL 1040;NORIDUR 1.4593 Type of bearing Plain bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 500 1/min Maximum flow rate 754 m³/h Maximum discharge-side pressure 40 bar Casing material (EN standard) 1. 4408;1.7709;GP240GH+N;NORIDUR 1.4593 No. of impeller entries Single entry Casing material Cast steel; Cast stainless steel Minimum flow rate 1 m³/h Suction characteristics Non- priming Drive voltage Low voltage eClass assignment 36410101; 36410100;36410000 Pull-out design Yes Pump set location Dry installed Heatable Yes Max. permissible fluid temperature 200 002 Main applications Industry and process engineering; Energy Type of installation Stationary Type of casing Volute casing Type of connection Flange Type of lubrication Product lubrication Type of drive Electric motor Installation position Horizontal or vertical Shaft material (EN standard) 1. 4313+QT780;1.4462 Type of coupling Direct Shaft seal type Magnetic drive Maximum head 236, 00 m Maximum rated pressure (discharge) PN 40 Minimum head 3, 50 m Nozzle position End suction Casing partition Radially split
    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • CHTC (ULTRA-HIGH PRESSURE PUMPS), KSB INDONESIA
    Design 
    Horizontal, high-pressure barrel-type pump with radial impellers, single- and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI. 
    Applications 
    Handling of feed water and condensate in power stations and industrial facilities, generation of pressurized water for bark peeling machines and descaling equipment. Overview of technical data Type of installation Long- coupled Type of bearing Plain bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 6. 750 1/min Maximum flow rate 1. 278 m³/h Maximum discharge-side pressure 400 bar No. of impeller entries Single / Double entry Casing material Carbon steel; Chrome steel Suction characteristics Non- priming Drive voltage Low voltage, high voltage eClass assignment 36410000; 36410101;36410100 Pull-out design Yes Other impeller types Closed / Radial Barrel casing Yes Pump set location Dry installed Type of suction casing Annular casing Max. permissible fluid temperature 200 002 Type of discharge casing Annular casing Type of first impeller Single entry Main applications Energy; Industry and process engineering Type of installation Stationary Type of connection Flange, weld ends Type of lubrication Grease / Oil / Pressurized oil lubrication Type of drive Electric motor, turbine Installation position Horizontal Maximum suction pressure 30 bar Type of coupling Geared variable speed coupling; Gear;Variable speed coupling;Direct Shaft seal type Mechanical seal Maximum head 4. 000,00 m Maximum rated pressure (discharge) PN160; PN250; PN320; PN400 Type of stage casing Stage casing with diffuser Nozzle position Variable Casing partition Radially split
    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571
  • CPKN(VOLUTE CASING PUMPS)KSB INDONESIA
    Design 
    Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with "wet" shaft, conical seal chamber, heatable volute casing (CPKNO-CHs) and/or semi-open impeller (CPKNO). Design to ATEX. 
    Applications 
    Handling of aggressive liquids in the chemical and petrochemical industries as well as in refinery and fire-fighting systems, handling of brine. Overview of technical data Type of impeller Closed; Radial Type of installation Long- coupled Maximum drive rating 3. 200 kW Impeller material (EN standard) NORIDUR 1. 4593;JL 1040;1.4408 Type of bearing Rolling element bearings Drive frequency 50 Hz / 60 Hz Maximum speed of rotation 3. 500 1/min Maximum flow rate 4. 800 m³/h Maximum discharge-side pressure 25 bar Casing material (EN standard) NORIDUR 1. 4593;1.4408;JS 1025;GP240GH+N No. of impeller entries Single entry Casing material Cast stainless steel; Ni-Resist;Cast duplex steel;Cast steel;Nodular cast iron Minimum flow rate 1 m³/h Suction characteristics Non- priming Drive voltage Low voltage eClass assignment 36410000; 36410100;36410101 Pull-out design Yes Pump set location Dry installed Heatable Yes Max. permissible fluid temperature 400 002 Main applications Energy; Industry and process engineering Type of installation 00 Type of casing Volute casing Type of connection Flange Type of lubrication Oil lubrication Type of drive Electric motor Installation position Horizontal Shaft material (EN standard) 1. 4462;1.5680;C 45+N;1.7709 Type of coupling Direct Shaft seal type Mechanical seal Maximum head 275, 00 m Maximum rated pressure (discharge) PN 25 Minimum head 2, 00 m Standard ISO 5199; ISO 2858;EN 22858 Nozzle position End suction Casing partition Radially split
    • Head Office, Factory & Service Kab. Bekasi
    • +6221 8998 3570
    • +6221 8998 3571